INFRASTRUCTURE, SECURITY & RESILIENCE

Plan for system failures.
Define the controls.

Trading systems must account for disrupted connections, uncertain order state, changing data quality, and privileged access. MarketTeck works with each firm to define controls, validation work, and operating responsibilities for the systems in scope.

The requirements below are established for each engagement. Implementation, validation evidence, and operational responsibilities depend on the agreed scope.

01 / ARCHITECTURE & CONTROL

Preserve the firm’s
operational boundaries.

Assess deployment within the firm’s infrastructure, dedicated environments, or approved managed services against its security requirements, connectivity, latency budget, and operating model.

  • Separate trust zones. Define boundaries between research, production execution, market data, management access, and client collaboration. Restrict permitted service-to-service connections.
  • Control privileged access. Integrate with approved enterprise identity, require strong authentication, and use time-limited, attributable administrative access with independent approval where required.
  • Protect intellectual property. Define who can access strategy code, models, datasets, and credentials. Establish project isolation, key ownership, data residency, retention, and restrictions on external tools.
  • Make ownership explicit. Assign responsibility for infrastructure, broker and exchange connectivity, release authority, risk limits, incident response, and recovery before production access.

02 / EXECUTION SAFEGUARDS

Constrain unintended
system behavior.

For execution-related engagements, agree safeguards with the firm’s trading, risk, and technology owners. Application controls must be considered alongside broker and venue controls.*

  • Pre-trade checks. Define applicable order-size, price, exposure, position, and message-rate limits, including authority to change them and behavior when checks are unavailable.
  • Order lifecycle integrity. Specify handling of duplicate submissions, retries, partial fills, late acknowledgments, reconnects, and uncertain order state.
  • Emergency intervention. Define who can stop new orders and initiate cancellation, the scope of each action, independent access paths, and confirmation of results. Sending a cancel request does not establish that an order was cancelled.
  • Controlled restart. Reconcile orders, fills, positions, and limits against authoritative sources before resuming. Document conditions requiring human authorization.

Controls are selected for the system’s role and connectivity. They do not guarantee prevention of loss or replace the firm’s risk oversight. Return to reference

03 / MARKET DATA & STATE

Establish when data
can be trusted.

Availability alone is insufficient. A system must distinguish usable information from stale, incomplete, inconsistent, or incorrectly sequenced inputs.

  • Data quality and lineage. Record sources, entitlements, normalization rules, instrument mappings, and transformations. Detect gaps, duplicates, stale feeds, and abnormal values.
  • Timing and sequencing. Specify clock synchronization, timestamp semantics, ordering assumptions, and monitoring appropriate to the system’s precision requirements.
  • Degraded operation. Define when to reject input, suspend affected functions, switch sources, or require operator review. Test transitions and recovery instead of assuming fallback data is equivalent.
  • Reproducible investigation. Retain approved versions of code, configuration, model inputs, and relevant event records so incidents can be reconstructed within confidentiality and retention constraints.

04 / RESILIENCE & RECOVERY

Prove behavior under failure.

Failure containment

Map dependency failures and shared failure modes. Evaluate network partitions, provider outages, resource exhaustion, and process failure. Prevent competing instances from both assuming execution authority.

Recovery objectives

Agree maximum tolerable disruption and data loss by service. Select redundancy, replication, backup, and recovery arrangements against those objectives and the firm’s infrastructure.

Demonstrated recovery

Exercise failover, restoration, reconciliation, and controlled re-entry. Measure recovery against the agreed objectives and record exceptions. Restoring a server is not proof that trading state is correct.

05 / CHANGE ASSURANCE

Make production changes
traceable and reversible.

Release decisions should be supported by evidence appropriate to the system’s financial and operational impact.

  • Independent review. Separate implementation and production approval, with traceable requirements, threat analysis, and failure-mode assessment.
  • Supply-chain controls. Inventory dependencies, review vulnerabilities and licenses, scan code and secrets, and preserve build provenance and approved artifacts.
  • Representative validation. Use replay, simulation, integration tests, capacity and tail-latency measurements, and deliberate fault scenarios. Validate risk controls separately from strategy behavior.
  • Controlled introduction. Define rollout limits, monitoring, stop conditions, and rollback or roll-forward procedures. Account for schema, state, and order-side effects that a code rollback cannot undo.

06 / OPERATIONS & ACCOUNTABILITY

Define who responds.
And what they can do.

Operational coverage and escalation must match the firm’s trading sessions and the criticality of each service.

  • Trading-aware monitoring. Cover data freshness, connectivity, order acknowledgments and rejects, reconciliation breaks, latency, capacity, and security events—not only server uptime.
  • Incident authority. Identify incident command, trading-risk escalation, emergency access, communication channels, and authority to suspend or restore services.
  • Evidence and investigation. Protect audit records from unauthorized alteration. Define access, retention, timestamp quality, and handling of confidential information during investigation.
  • Lifecycle responsibility. Agree vulnerability remediation, maintenance, support hours, subcontractor access, handover, and termination procedures. Staffing and service commitments must be confirmed contractually.

TECHNICAL DUE DILIGENCE

Review the evidence
before operational handover.

Agree which architecture records, test results, and operating documents your team needs to assess the work and take responsibility for the system.

Before implementation

Architecture and data-flow diagrams; system boundaries; threat and failure analysis; control ownership; confidentiality and data-handling requirements; measurable acceptance criteria.

Before production

Test and security-review results; dependency inventory; access approvals; risk-control validation; capacity and failure-recovery evidence; release and operational-readiness approval.

During operation

Change records; access reviews; service and incident reports; remediation status; recovery exercises; updated runbooks and exit documentation.

For common questions about infrastructure, portal access, and security assurances, see Q&A.

Design references: FIA automated trading controls and safeguards and NIST cyber-resilient systems engineering. Their use as references does not establish certification or conformity.

ENGINEERING DISCOVERY

What technical challenges
can we help resolve?

Discuss your firm’s engineering objectives and operating environment.
Confidential strategy details are not required for an introduction.

Contact our team ↗